Model No.: PE60AA
Rated Power: 45-60Watts
Input Voltage: 90-277V
Output Voltage: 12-24V
Output Current: 0-2500mA
Power Factor: 0.95-0.98PF
- Universal AC input (up to 265VAC)
- With the active Power Factor Correction function
- Protections: short circuit/over voltage/over current /no-load
- Natural cold wind
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Big wiring terminal locked by screw
- Suitable for LED home lighting, commercial lighting and etc.
- Safety no load protection device
- Economic and convenient installation
- Conform to the world lighting equipment safety standards
- Protection class II
- Three years warranty
Electrical specification
Model No |
PE60AA24 |
PE60AA30 |
PE60AA36 |
PE60AA42 |
PE60AA48 |
PE60AA54 |
|
Output |
Rated power |
60W |
60W |
61.2W |
60.9W |
62.4W |
62.1W |
Direct voltage |
24V |
30V |
36V |
42V |
48V |
54V |
|
Constant current range |
15-24V |
18-30V |
22-36V |
25-42V |
38-48V |
32-54V |
|
Voltage accuracy |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
|
Constant current |
2500mA |
2000mA |
1700mA |
1450mA |
1300mA |
1150mA |
|
Constant current accuracy |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
|
Linear adjustment rate |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Ripple voltage(max) |
150mVp-p |
200mVp-p |
200mVp-p |
300mVp-p |
300mVp-p |
300mVp-p |
|
Start-up, rise time |
1500ms,80ms/115VAC(full load);1000ms,80ms / 230VAC(full load) |
||||||
Retention time |
16ms/230VAC 16ms/115VAC(full load) |
||||||
Input |
Voltage range |
90~305VAC |
|||||
Frequency range |
47 ~ 63Hz |
||||||
Power factor correction |
PF>0.98/115VAC, PF>0.95/230VAC,PF>0.92/277VAC(full load) |
||||||
efficiency (Typ.) |
89.5% |
90% |
90% |
90% |
90.5% |
90.5% |
|
Alternating current |
0.64A /115VAC 0.32A/230VAC 0.3A/277VAC |
||||||
Surge voltage (Typ.) |
Cold start:70A/230VAC |
||||||
Leak current |
<0.75mA /277VAC |
||||||
protection |
Over current |
95 ~ 108% protection mode: constant current limit mode, the load can be restored automatically after removing the abnormal condition |
|||||
short-circuit |
Hiccup mode: recover automatically after removing abnormal condition, |
||||||
Over voltage |
35V |
43V |
49V |
58V |
63V |
68V |
|
Protection mode: turn off the output voltage, recovery after restarting |
|||||||
Over temperature |
95℃±10℃ Protection mode: turn off the output voltage, recovery after restarting |
||||||
Environment |
Operating temperature |
-40~ +70℃ |
|||||
Operating humidity |
20-85%RH |
||||||
Storage temperature humidity |
-40~ 85℃ 10~95%RH |
||||||
Temperature coefficient |
±0.03%/℃(0-60℃) |
||||||
Safety and electromagnetic compatibility |
Safety standard |
EN 61347-2-13:2006 /EN 61347-1:2008 |
|||||
Withstand voltage |
I/P-O/P:3.75KVAC |
||||||
insulation resistance |
I/P-O/P:100M Ohms / 500VDC /25℃/70%RH |
||||||
Electromagnetic interference |
EN55015 |
||||||
Harmonic current |
EN6000-3-2/EN6000-3-3 |
||||||
Electromagnetic susceptibility |
EN6000-4-2 |
||||||
Other |
Dimension |
(L*W*H) = 209mm * 76mm * 49mm |
|||||
packaging |
|
Your Contact Details To Us
Your E-Mail:*
Fax Number:
Your Company:
Your Homepage:
Your Name:
Tel Number:
Your Inquiry To Us
Subject:*
Content:*
Rated Power:150W
Input Voltage:200V-250V
Rated Power:30-45W
Input Voltage:200-250V
Rated Power:3-12Watts
Input Voltage:200-250V
Rated Power:3W-12W
Input Voltage:200-250V
Rated Power:18-30Watts
Input Voltage:200-250V
Rated Power:18W-30W
Input Voltage:200-250V
Rated Power:120Watts
Input Voltage:200-250V
Rated Power:120Watts
Input Voltage:200-250V